Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 90 of 90 items found.

  • One Phase Electric Power/Energy Calibrator

    MC133 - Powertek LLC

    The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.

  • 8/16-CH 16-Bit Analog Output Cards

    PCI-6208/6216 Series - ADLINK Technology Inc.

    ADLINK PCI-6208/6216 series are 8 or 16-CH, 16-bit, analog output cards. The PCI-6208V-GL offers 8 voltage outputs with ±10 V range, featuring 15-bit monotonicity and 10 V/μs slew rate. The on-board analog switches minimize the power-on glitches. PCI-6216V expands the voltage output channels to a total of 16 for higher analog output density requirements. In addition to the voltage output functions, the PCI-6208A features 8 current outputs with ranges of 0-20 mA, 4-20 mA, and 5-25 mA. The daughter board EXP-8A provides high-quality voltage to current transducers. The PCI-6208A device is capable of delivering 14-bit monotonicity with 1.3 mA/μs slew rate. ADLINK PCI-6208 series devices provide high-resolution, high-density analog output functionalities and are suitable for ATE, signal generation, industrial process control, servo control and other industrial control applications.

  • Integrated Laser Controller

    ILC - AOSense

    AOSense has developed a compact Integrated Laser Controller (ILC) that can be paired with our External Cavity Diode Lasers (ECDLs) to control laser current, piezo transducer (PZT), and temperature. The ultra-low noise electronics are fully digitally controlled. The ILC dimensions are only 5″x2.9″x0.95″. We provide software with an easy-to-use graphical user interface (GUI) that can control multiple lasers from a single window. If preferred, commands may be sent over a USB virtual COM port. The software screenshot below (click the image to enlarge) shows the interface including a plot of the temperature (green line) as it settles to a commanded value.

  • Power modules

    G.R.A.S. Sound & Vibration A/S

    It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • Calometric Power Meter

    M1-25M/XXE - Elmika

    The M1-25M/XXE series instruments are high precision broadband Calorimetric Sensors operating in millimeter and sub-millimeter wave range on a principle of substitution of microwave power by direct current power, using an autocompensating transistor transducer. Calorimetric Sensor is supplied with Calorimetric Power Meter M1-25M (measurement and indicator block), which provides PC connection via USB interface.Calorimetric Power Meter with Calorimetric Sensor provides accurate absolute power measurements in single mode and multimode waveguides (Metal Dielectric Waveguide) which could be a priority for terahertz physics and technology.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Intelligent A/D I/O Unit

    RAD242 - Acces I/O Products, Inc.

    Model RAD242 is an intelligent, two-differential-channel, 24-bit analog-input interface unit that includes a Delta-Sigma A/D converter. The converter has a digital output filter with adjustable notch frequency from 10 Hz to 2000 Hz. The pod also has 13 bits of digital input/output. A precision 10 VDC voltage that can be used for transducer excitation is available at connector pin 5. As much as 60 mA current can be provided. It is packaged in a NEMA 4 enclosure for remote installation in harsh environments. RAD242 also provides a user-definable interrupt input and counter/timer input. An optional RAD Firmware Development Kit is available if you wish to use those user-programmable input lines or to develop a custom program.

  • PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module

    781490-01 - NI

    204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module

    781369-01 - NI

    204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module

    781370-01 - NI

    204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • Circuit Breaker Analyzers & Timers

    IBEKO Power AB

    CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

Get Help